Apogee Symphony I/O Mk II SoundGrid Руководство пользователя - Страница 12
Просмотреть онлайн или скачать pdf Руководство пользователя для Оборудование для звукозаписи Apogee Symphony I/O Mk II SoundGrid. Apogee Symphony I/O Mk II SoundGrid 20 страниц. For units equipped with the wsg option card
Clock Screen
Use the Clock page to set the clock source and sample rate for the device and to assess clock status. Clock
controls are on the left side of the page, status indicators are on the right.
● Source - Sets the clock source.
○ Internal - The Symphony I/O Mk II's internal clock is used
○ External WC - Clock is provided by an external device via the Symphony I/O Mk II's Word Clock
Input connector
○ Digital - Clock is provided by an external device via the Symphony I/O Mk II's digital audio input
connector. When this option is selected, additional settings appear:
─ SPDIF Coax - Clock is provided to the selected SPDIF Coax input
─ ADAT - Clock is provided to the selected ADAT optical input
─ AES - Clock is provided to the selected AES input
● Sample Rate - Sets the sample rate when Clock Source is set to Internal.
○ Sample Rate can be set to 44.1 / 48 / 88.2 / 96 kHz.
─ If Source is set to anything other than Internal, the Sample Rate menu is grayed out and
inoperative.
─ A SoundGrid system's maximum sample rate is 96kHz
● Input Word Clock Termination - Terminates the BNC Word Clock Input connector on the rear panel of
Symphony I/O Mk II. In general, leave this Input Termination on at all times. This applies even when
Symphony I/O Mk II is being used as the master clock for other devices. The only time this should be
turned off is when Symphony I/O Mk II is slaving to external clock AND passing the signal through the
BNC Out to another device.
APOGEE SYMPHONY I/O MK II SOUNDGRID USER'S GUIDE
Page 12