635/636 CONTROL BOARD ADJUSTMENTS
OFF
ON
Factory
Description
Setting
#1
OFF
TIMER TO CLOSE - Automatically closes gate
ON - Close timer enabled
#2
OFF
CURRENT SENSITIVITY OPTION - Delays current sensing from start
ON - 4 second delay
#3
ON
TIMER TO CLOSE OPTION
ON - timer to close works only when open limit switch is activated
OFF - timer to close works from any open gate position
#4
OFF
DUAL CONTROL SLAVE OPTION
ON - disables slave side of dual board
OFF - enables slave side of dual board
#5
OFF
DUAL CONTROL MASTER OPTION
ON - disables master side of dual board
OFF - Enables master side of dual board
#6
OFF
MAXIMUM RUN TIMER OPTION
ON - stops and reverses gate if run timer times out before closing
OFF - stops gate if run timer times out before closing
#7
ON
MAXIMUM RUN TIMER VALUE
ON - 40 seconds
OFF -20 seconds
#8
ON
TIMER TO CLOSE VALUE
ON - 20 to 70 seconds (adjustable)
OFF - 10 to 35 seconds (adjustable)
#9
OFF
OPEN, STOP, CLOSE CONTROL ENABLE
ON - allows for open, stop, close unit (optional) to operate gate
OFF - normal operation
(If 9 is on, terminals 4 & 5 must be normally closed for proper operation.)
TIMER
TO
CLOSE
CURRENT
SENSITIVITY
LED ENABLE
PROGRAM SWITCHES
OFF - Close timer disabled
OFF - 2 second delay
TIMER TO CLOSE ADJUSTMENT
Rotate clockwise to increase time before gate closes.
Rotate counter clockwise to decrease time before gate closes.
If program switch #3 is on, the gate must activate the open limit
switch in order for the timer to close to operate.
Rotate clockwise to decrease sensitivity (more force).
Rotate counter clockwise to increase sensitivity (less force).
WARNING: The CURRENT SENSITIVITY should be adjusted to
prevent injury in the event of someone being entrapped in the gate.
This feature should be periodically tested to assure proper operation.
Refer to SAFETY PRECAUTIONS.
Enables LEDs for installation and troubleshooting (must be de-
pressed to observe LEDs).
There are 4 standard automotive type fuses on the 635/636 circuit
board. The EMERGENCY BY-PASS plug is protected by a 15 Amp
fuse. The remaining three fuses (one for each of the 12 Volt outputs)
are 3 amp.
11
CURRENT SENSITIVITY
LED ENABLE
Fuses