Apollo Sprayers T6000 사용 설명서 - 페이지 7
{카테고리_이름} Apollo Sprayers T6000에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Apollo Sprayers T6000 11 페이지. Mist applicator
4
Adjusting your Mist Applicator
a. Locate the Solution Flow Screw (#10) on the T6000 diagram.
b. Turning the Solution Flow Screw clockwise reduces and will eventually stop the flow of solution. DO NOT
over-tighten the screw as this will cause damage to the end of the needle. Once the trigger cannot be
pulled back there is no point in tightening the screw down more, this will only damage the end of the
needle.
c. Turning the Solution Flow Screw anti or counter clockwise will increase the flow of solution.
d. In general, 1 ½ - 2 full turn from the fully closed position will provide a good solution flow. You may find
that you want more or less solution. You can adjust the Solution Flow Screw to your desired setting.
NOTE: Opening the Solution Flow Screw more than 3 turns will not increase the solution flow and will in
fact decrease the efficiency of your Mist applicator.
e. In general, hold the T6000 Mist applicator 4" (10cm) from the person being sprayed. Moving the Mist applicator
back will increase the size of the mist pattern. Moving the Mist applicator closer will decrease the size of the
mist pattern. The further away you hold the Mist applicator, the more you will need to increase the solution
flow thus causing abnormal amounts of airborne solution (overspray).
f.
Holding the Mist applicator closer to the person being sprayed along with a minimum flow of solution will
provide the best results, no streaks or running solution and virtually no mist in the spray area.
g. Be sure to move the Mist applicator at a slow, steady speed keeping the distance of the Mist applicator the same
throughout the application. This will ensure perfect results. It is actually very easy. Practice a few times
and you will be an expert.
h.
It is best to hold the Mist applicator in a vertical position when spraying. If you want to change the direction of
the mist pattern, rotate the position of the air cap rather than turning the Mist applicator on its side.
i.
Always hold or store the Mist applicator in a vertical position. A slot in the T100 Turbo Unit is provided to hold
and store the Mist applicator. It is a good habit to use it when you are not spraying.
j.
Do not over-tighten the solution flow screw (#10) as this will damage the end of the needle point. Tighten
the screw until the needle cannot be pulled back. Once this point is reached there is no point in turning
the solution slow screw anymore as this will only cause damage to the needle point.
5
Spraying/Misting
7