Once the limit switches are adjusted turn the power on to the MCSv2 control card and follow on
screen instructions to profile the gate. The MCSv2 control card has been specially configured
to be used with iS motor kit. For replacements please contact Elsema PTY.
Control Inputs
Push button
: N/O input acts as a OSC (open, stop, close) input.
Open
: N/O input acts as a open only (swipe mode) input.
Close
: N/O input close only input (force close) input.
Ped Access
: Used for initiating a partial opening.
Photo Beam (P.E) : N/C safety input. Can be set for N/O operation if needed through menu 3.1.
PE beam operation modes can be changed through menu 4.2.
Control Outputs
12VDC
: Supplies regulated 12VDC at a max of 250mA, can be used for accessories such as pe
cells warning devices etc, but must not exceed 250mA.
24VDC
: Supplies 24VDC 1.0A regulated output, this can be used for higher power usage devices
such as induction loops. This output is fused at 1.0 A.
Output 1
: N/O dry contact relay output. Do not exceed 5A load. Can be set for various functions
through menu 5.1 default is Lock/Brake.
: Open Collector output. Can be used with Elsema's REL 1-12 relay card.
Output 2
C
B
L
ONTROL
OARD
AYOUT
6