6. COMMISSIONING THE UNIT
1. Remove the weather protection hood (if provided).
2. Check that the gas is connected correctly to the gas cylinder
and open the cylinder.
Secure the gas cylinder with the rubber mounting piece.
6.1 SWITCHING THE UNIT ON
1. Turn the ignition knob on the gas control panel (Fig. 4) as far to the right as possible. Push in the ignition knob. Then, turn it to
the left, keeping it pushed in until you hear a "click" (Fig. 5). This "click" is the ignition of the pilot light. If necessary, repeat this
process 3-5 times until the pilot light is burning.
2. Once the pilot light is lit, continue holding in the ignition knob for another 10 seconds. Then release the ignition knob.
3. If the pilot light goes out, repeat steps 1 and 2 until the pilot light starts burning.
Caution: If a new gas cylinder is installed or the fireplace has not been used for a while, you first have to release the air from the
gas hose. This may take a while before the pilot light ignites.
6.2 BURNER FLAME
After the pilot light starts burning, the ignition knob (Fig. 6) has to be turned to the left. Now the main burner (Fig 1) is supplied with gas.
6.3 ADJUSTING THE FLAME HEIGHT
1. The desired height of the gas flame can be adjusted by turning the flame height controller (Fig. 7) to the right or left.
2. For a lower gas flame, turn the knob clockwise to the right (Fig. 8).
3. For a higher gas flame, turn the knob clockwise to the left (Fig. 7).
6.4 SWITCHING THE UNIT OFF
1. By turning the ignition knob to the right again (Fig. 4), you will shut off the gas supply and the fire will go out.
Then, the gas cylinder has to be closed.
6.5 WARNING – IF YOU SMELL GAS
Never ignite the unit if you smell gas. If the unit is on when you smell gas, you have to interrupt the gas supply (close the gas
cylinder or the gas valve). Then, check all of the connections for leaks. To do so, moisten all of the gas connections with soapy
water or use a gas leak detection spray. If bubbles arise in the suds or the gas leak detection spray, there is a leak. You can only
use the unit again after all the leaks have been sealed. Please consult your dealer, if necessary.