DUUN PT280 사용 설명서 - 페이지 15
{카테고리_이름} DUUN PT280에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. DUUN PT280 18 페이지.
Service and maintenance
Lubrication points
The lubrication points marked A are lubricated when the hydraulic height adjustment is fitted.
Lubrication interval: 50 operating hours.
The lubrication points marked B are lubricated when the hydraulic lateral adjustment is fitted.
Lubrication interval 50 operating hours.
Gearboxes
The gearboxes have oil change intervals. The first change must take place after 50 operating
hours. Later every 500 operating hours or every other year.
Manufacturer: Gardini
The lower gearbox is drained from the plug marked A. Filling the plug marked B
The upper gearbox must be sucked out of the oil through the upper plug marked C
Can also lay the tower down on its side and drain the oil through the plug marked.
Oil quantity: 1.3 litres
First of all
Before cleaning, lubricating, repairing or
adjusting the machine, stop the engine and
activate the handbrake and remove the key
during work. Pay special attention to safety
during maintenance work, park the machine
in accordance with specified safety rules.
Subsequent inspection of screw
connections. Screws - nuts - nipples and
bolts on the machine must be tightened after
two hours of operation.
Clean after use
Power transmission shaft
When the wide-angle shaft works with fixed
angle, the lubrication interval should be 2-4
hours to ensure the shaft has
sufficient supply of lubricating grease.
Interval: Every 2-4. operating hours.
Maintained in accordance with the attached
instruction manual. Please contact
supplier if this is missing
Grease quality: Good quality universal
grease.
15