Warning
For safe performance, this water heater
is fitted with:
1. Combination Thermostat and over-
temperature energy cut-out.
2. Combination Pressure &
Temperature Relief Valve.
These devices must not be tampered
with or removed.
The water heater must not be operated
unless each of these devices is fitted
and in working order. The element(s)
cover should be removed only by an
electrician.
The electrical power supply switch must
be turned off and the fuse removed or
the circuit breaker isolated at the main
electrical supply switchboard before the
water heater electrical cover is removed.
Open the PTR Valve for approximately
10 seconds by lifting the lever on the
valve to ensure water is relieved to waste
through the relief drain pipe. Lower lever
gently and check that it closes correctly.
The PTR Valve must not be tampered
with or removed. The water heater must
not be operated unless this valve is
fitted and in working order.
The PTR Valve should be checked for
adequate performance or replaced at
intervals not exceeding 5 years, or less
in areas where local regulations apply.
H0421
0421
Rev. J
Owner's Manual – Proflo Electric Storage Water Heaters
Safety Information
Important
The PTR Valve and its drain outlet pipe
must not be sealed or blocked. It is
normal for the PTR valve to leak a small
amount of water during heating cycles.
Danger
Failure to operate the relief valve easing
lever at least once every six (6) months
may result in a problem with the water
heater and in some cases the tank may
explode.
9