ADE PWI30 운영 매뉴얼 - 페이지 7
{카테고리_이름} ADE PWI30에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ADE PWI30 16 페이지. Electronic bench scales portion scale with induction charging
Assembling and levelling the scale
Carefully remove the delivery contents from the packaging.
Put the load cross on the scale. Make sure that the holes in the centre of the load cross sit
over the pin in the centre of the housing. Attach the load cross to the quick-release fastener.
Place first the silicone mat and then the weighing plate on the load cross.
Place the scale on a level and stable installation surface and make sure that all four feet are
in contact with it. In addition, check the footing of the scale by means of the spirit level, the
bubble of which should be in the centre of a circle.
Put the weighing bowl on the scale. The four pins of the weighing bowl should grip into the
appropriate scale openings.
Insert the AC adapter into the socket located below the scale next to the power button. Connect
the AC adapter to an AC power outlet (pay attention to the correct voltage).
Using the scale
Switching on the scale
To turn on the scale, press and hold down the
button for about three seconds.
The display will show "ADE" for two seconds and will then automatically switch to weighing
mode. "0,000" is shown on the display.
If this is not the case, press the
button. As a result, measurement inaccuracies will be
compensated after turning on the scale and will be reset to zero before the actual weighing
process.
The display now shows "0.000" and the
figure indicates the zero position.
shows that
the weight value is stable. The scale is now ready for use.
If the display shows only "0.00", please check the selected digit interval in the parameter
settings of the unit of weight.
Determining weight
Make sure that the display shows "0.000",
and
as described above.
Put the object to be weighed on the weighing surface. The weight value will appear on the
display and
will show that the weight value is stable.
Zeroing the scale
If the weight is lower than 10% of the maximum capacity (here: 3 kg) and the display shows
the stability symbol
, press the
button to perform the zeroing function.
The display will show "0.000",
and
.
Tare function
If the weight value is greater than or equal to 10% of the maximum capacity (here: 3 kg) and
the display shows
, press the
button to perform the tare function.
The display will show "0.000",
and
.
PWI30-190920-Rev005-UM-en
6