4qd Uni-4-12 사용 설명서 - 페이지 5
{카테고리_이름} 4qd Uni-4-12에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. 4qd Uni-4-12 8 페이지.
Wire size.
Use heavy duty wire for the battery, and make them
as short as possible. This also applies to the battery
linking wire on 24v systems. 4mm
adequate.
Use of wire that is too long (and/or too thin) will
cause loss of power and may also cause the
decoupling capacitor (see 'features' diagram above)
to heat up. Under extreme conditions the capacitor
can disintegrate. Heat will also shorten the operating
life of this capacitor. Once the capacitor fails the
current output will fall dramatically.
The only external control the UNI needs is a speed
pot, shown in the diagram, below left. There are other
controls that you may add if you wish.
The Uni turns itself off automatically when you turn
the speed to zero, so you can fit an on/off switch in
series with the red wire as shown in the diagram
below, right. Opening this will remove the voltage
from the pot, so the controller will run down to zero
sped and switch off.
With the pot at zero, the controller draws only a very
small current: (24v version, about 1.8 mA and the
12v version about 5,6mA)
The two diagrams below also show the wiring to the
connector (which is internal to the controller) so if
Red - max
A
B
Blue - wiper
C
D
Green - min
Uni Instructions
Power Connections
2
wire is generally
2
Max
Min
A
B
C
D
Motor wiring
This is not so critical as battery wiring: too long
and/or too thin wire will cause a loss of maximum
current, will get hot and will waste battery power but
will not damage the controller. However, wire which
is too thick will do no harm either so we recommend
the same wire for the motor as for the battery.
Battery wiring
Battery connections to the controller are shown in the
diagram, left. Use only good quality battery
connectors: a controller with regenerative braking
feeds current back into the battery during braking and
if a battery connector falls off when braking this
regenerated current can pump up the voltage on the
dud battery connection.
Controls
you have the cased version - ignore the connector.
If you aren't using the yellow wire, make sure it is
arranged so that it cannot touch anything: it carries
the full battery voltage. It is also possible to use these
four wires to connect a battery condition meter.
That's really all you need to know to get the Uni
working!
Pot fault detection
This feature is not normally engaged: for it to operate
you must fit a resistor as shown in the third diagram.
Use 3K3 with a 10K pot and re-adjust the gain
control. Typically it is enabled to prevent the
controller going to full speed in the event of a broken
wire to the pot.
Max
Min
Red - max
Blue - wiper
Green - min
Max
Min
Red - max
Blue - wiper
Green - min
Page 5