2.
Connections
The SCC-001 was designed to work with the DNO series of controllers and can be
plugged directly into the expansion port of the DNO. The pin connections are shown
below.
The SCC-001 can also work with other controllers by feeding a speed related positive
voltage into the speed terminal, and then adjusting the pot as required.
The SCC-001 has an upper voltage limit of 30V.
3.
Adjustment
For use with the DNO the pot should be adjusted fully clockwise. This gives a full
speed output for an input voltage of ~8V. For higher input voltages the pot should
be adjusted so that the maximum output signal corresponds to the vehicle top
speed.
SCC-001 V1.1 07/19