TROUBLESHOOTING

Anomaly
No atomization
Leakage from the
nozzle
10 - Instruction Manual
Problem / Solution
No pressure is getting to the gun
Check air system
Valve part. [1007- 43] worn out Replace
valve part. [1007-43] worn out
The head part. [1268-53] or [1268-79], the
nozzle part. [1268-52] or [1268-73], and the
needle part. [1268-54] are worn out.
Replace the head part. [1268-53] or [1268-79], the
nozzle part. [1268-52] or [1268-73] and the needle
part. [1268-54] worn out.
The product is exceeding the amount needed
Reduce the product passage
Lack of product (flow rate too low)
Add product or reduce atomization air
pressure
Missing product in tank or clogged pipes Fill
tank or clean up with solvent
Mounted handwheel part. [1268-63] worn out
Replace mounted handwheel part. [1268-63] worn
out
Needle part. [1268-54] / nozzle
part. [1268-52] or [1268-73] worn out
Replace needle part. [1268-54]/
nozzle part. [1268-52] or [1268-73] worn out