Gage Bilt GB703 설치 매뉴얼 - 페이지 14

{카테고리_이름} Gage Bilt GB703에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Gage Bilt GB703 20 페이지.

Gage Bilt GB703 설치 매뉴얼
WARNING:
Disconnect tool from its power source before actuator removal or installation. Severe personal injury may
occur if power source is not disconnected.
CAUTION:
Actuator assy-air can break if not careful.
CAUTION:
Do not over tighten air actuator assy. Snug tighten only.
REMOVING 704130 ACTUATOR ASSY-AIR
1.
Insert a 5/8" (15.9 mm) open end box wrench around actuator assy-air (704130).
2.
Loosen the actuator assy-air (704130).
3
Remove wrench. Unthread and remove the actuator assy-air (704130) with fingers from the
handle assy (704132).
INSTALLING 704130 ACTUATOR ASSY-AIR
1.
Apply Teflon® tape onto threads of actuator assy-air (704130) one to two wraps.
2.
Thread the actuator assy-air (704130) all the way into handle assy (704132) with fingers.
3.
Insert and turn 5/8" (15.9 mm) open end box wrench and snug tight approximately 1/4-1/2 turn.
S/N: 3191 AND ABOVE
PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS.
OVERHAUL
ACTUATOR-AIR
14
4/12 Rev. 1/17