Gage Bilt GB703 Kurulum Kılavuzu - Sayfa 14
Elektrikli Alet Gage Bilt GB703 için çevrimiçi göz atın veya pdf Kurulum Kılavuzu indirin. Gage Bilt GB703 20 sayfaları.
WARNING:
Disconnect tool from its power source before actuator removal or installation. Severe personal injury may
occur if power source is not disconnected.
CAUTION:
Actuator assy-air can break if not careful.
CAUTION:
Do not over tighten air actuator assy. Snug tighten only.
REMOVING 704130 ACTUATOR ASSY-AIR
1.
Insert a 5/8" (15.9 mm) open end box wrench around actuator assy-air (704130).
2.
Loosen the actuator assy-air (704130).
3
Remove wrench. Unthread and remove the actuator assy-air (704130) with fingers from the
handle assy (704132).
INSTALLING 704130 ACTUATOR ASSY-AIR
1.
Apply Teflon® tape onto threads of actuator assy-air (704130) one to two wraps.
2.
Thread the actuator assy-air (704130) all the way into handle assy (704132) with fingers.
3.
Insert and turn 5/8" (15.9 mm) open end box wrench and snug tight approximately 1/4-1/2 turn.
S/N: 3191 AND ABOVE
PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS.
OVERHAUL
ACTUATOR-AIR
14
4/12 Rev. 1/17