Program and Service Mode Functions
Programming is done through the 4 hidden buttons located on the brewer faceplate under the display.
Prior to accessing the program or service mode you will need to attach a service template to the faceplate of the
unit in order to locate the buttons. Attach one of the self stick templates to the faceplate aligning it with the display
window edges and bottom border as shown in Fig 1 on page 2.
To enter either the Program or Service Mode:
Turn the main ON/OFF switch located on the lower left front of brewer column to the OFF position.
Depress and hold down both the Brew and Cancel Buttons located on the brewer face plate. (See Fig 1, Page 2).
Continue to hold while turning the ON/OFF switch to the ON position. The brewer display will indicate to please
wait as it initializes the program/service mode. Continue holding the brew and the cancel button until the brewer
enters the Program/Service main menu (approximately 5 seconds).
Select Mode
Program
Service
The service mode is used for initial brewer fill, to display and clear error messages, to view total brew cycles, and
to view/reset the brew cycles since service.
An explanation of the various features for both modes is outlined in the following sections. Note that if at
any point after entering this menu the brewer detects that there has been no activity on the keypad for 1 minute it
will exit to the ready/standby mode. It will then be necessary to follow steps outlined above to return to the program
or service mode. If an option or feature has been changed without pressing enter prior to this occurring the change
will be lost.
Program Options
Option
Brew Time #1
Brew #2 Enable
Brew Time #2
Buzzer Delay
Auto Arm Enable
Brew Time Remaining
Temperature Setpoint
Power Save Enable
Buzzer Type
Keypad Beep Enable
Service Cycles
Exit Pgm/Srv Mode
Brew Time #1
3:30
or "+" keys may be used to change the selected numeral up or down as required to obtain the desired brew time.
Note that when setting brew time the display changes by 1 numeral each time the button is depressed. The
minimum time which may be programmed is 10 seconds and the maximum time is 5 minutes and 20 seconds.
Depress enter to save the programmed brew time.
Brew #2 Enable
Yes
No
This is the Program/Service main menu. Use the Select key to choose either the
Program or Service mode. The program mode is used to set custom settings such
as brew times, buzzer type, tank temperature, enable power save or auto arm, etc.
Table 1 - Summary of Program Mode Options/Features
Program Options/Value Range
10 Sec - 5 Min, 20 Sec
Yes, No
10 Sec - 5 Min, 20 Sec
10 Sec - 2 Min
Yes, No
Yes, No
170 F - 212 F
Yes, No
Time is factory set at
2 hours. May not be changed.
Burst, None, Steady, Single Pulse, Double
Pulse
Yes, No
0 - 65535
Yes, No
This is the length of time which the dump valve will remain open to allow water to
flow over the coffee grounds. It is the active portion of the brew cycle. The Select
key may be used to choose a numeral in the displayed time to change and the "-"
This option allows a second brew function to be programmed thereby giving the
user multiple volume brewing capability. Brew #2 is the brew cycle which would be
Factory
Setting
3:25
Dump valve open time for brew 1.
No
Optional second brew setting using hidden key.
1:30
Dump valve open time for brew 2.
1:00
Drain time from basket for brews 1 and 2.
Yes
Ensures optimum brew temperature.
Yes
Display time remaining during the brew cycle.
205
Water holding temperature in tank.
Yes
Drops tank temperature to 170 F during
periods (2 hours) of non use to save energy.
Steady
Signal for the completion of the brew cycle.
Yes
Audible tone to ensure keys are fully
depressed.
500
Brew Cycles to run before displaying the Call
For Service Message for routine maintenance.
N/A
Exit from programing mode to "Ready To
Brew".
- 4 -
Description