Hi-Force TWE Series 사용 설명서 - 페이지 15

{카테고리_이름} Hi-Force TWE Series에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Hi-Force TWE Series 20 페이지. Electric torque wrench

Hi-Force TWE Series 사용 설명서
Prepared by:-
M.DAVIES
REV NO:-
1
ECO:-
The two diode lights flash red alternately. The
error is documented.
Remedy: Unplug the tool and plug in again. If
the error is still present, send device to Hi-Force
Limited.
3.5.2 Error in the temperature sensor
If there is any error in temperature
measurement, the message Sys02 flashes in the
display for 3 seconds.
Bolting process is interrupted.
Additionally, an acoustic warning signal is
emitted.
The two diode lights flash red alternately. The
error is documented.
Remedy: Unplug the tool and plug in again. If
the error is still present, send device to Hi-Force
Limited.
3.5.3 Error motor overcurrent
If there is any error in motor over-current, the
message Sys03 flashes in the display for 3
seconds.
Bolting process is interrupted.
Additionally, an acoustic warning signal is
emitted.
The two diode lights flash red alternately. The
error is documented.
Remedy: Unplug the tool and plug in again. If
the error is still present, send device to Hi-Force
Limited.
Cause: Blockage of motor in clockwise rotation,
or short circuit in the coil.
OPERATING INSTRUCTIONS:
Electric Torque Wrench
Series: TWE
Approved by:-
Page 15 of 20
TDS:-
1399
Date: 25/03/14