Gaggenau VG 232 CA 작동 및 조립 지침 매뉴얼 - 페이지 9

{카테고리_이름} Gaggenau VG 232 CA에 대한 작동 및 조립 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Gaggenau VG 232 CA 20 페이지. Gas cooker vg 232 ca operating and assembly instructions
Gaggenau VG 232 CA에 대해서도 마찬가지입니다: 작동 및 조립 지침 매뉴얼 (14 페이지)

Gaggenau VG 232 CA 작동 및 조립 지침 매뉴얼

2.3 Operating principle

Fig. 4
8
The appliance features one-hand operation. That
is to say, the ignition is activated when the control
knob is pressed briefly.
After igniting, keep the control knob pressed for
around 5-8 seconds more because the heat sensor
that opens the gas channel has to warm up first.
The gas hob has 2 normal burners and 2 high-
intensity burners.
All burners have a thermal protection device that
prevents unburned gas from escaping in the open
position.
Off
The total rated thermal load amounts to:
32 000 BTU (9.4 kW) referred to H s * (gross calorific
28 600 BTU (8.4 kW) referred to H i (calorific value)
The specified rated load is defined by installation
of the fixed nozzles.
The gas hob is converted to a different gas
type by nozzle replacement (full and low-burning
nozzles) (see nozzle table on page 12).
The symbols on the control panel mean:
0 Off
High setting
Low
Low setting
The flame is infinitely variable between high and
low-setting.
Maintenance Instructions
– Keep appliance area clean and free from
combustible materials, gasoline and other
inflammable vapors and liquids.
– Do not obstruct the flow of combustion and
ventilation air.
High
– Visually check burner flames with this pictorial
representation (see figure 4).
value)