HYDRALITE
Fig.2
Function
(read in conjunction with Fig. 2)
The permissible working load and the travel of the hydraulic jack is marked on the equipment,
also see table 1.
The jack has an in -built hydraulic pump, which is worked by means of an operating lever ( 1),
under the control of the operator. The jack ram ( 2) is raised on each downward stroke of the
lever. For lifting, the operating lever (1) is placed fully into the operating quadrant ( 3).
Three positions are provided to enable the operator to choose the best ergonomic position. For
lowering, the lever is removed from the quadrant and placed into the release screw ( 4). Turning
this anti -clockwise will allow the ram to descend. The amount this is rotated will control the
speed of descent; only open a very small amount (approx. 5°) at first.
Close the relea se valve, to ready the jack for the next operation.
After use store the jack in an upright position with the ram fully retracted and the operating
quadrant in the 'up' position.
Table 1
Model
PS620
PS1220
PS630
PS1230
PS660
PS1260
P6100
Capacity (ton ne)
20
20
30
30
60
60
100
Add:
S
for Screwed Ram (for example PS620S)
C
for Claw (for example PS620C)
Stroke (ins)
Claw Capacity (ton ne)
6
12
6
12
6
12
6
8
8
12
12
24
24
N/A