Hi-Velocity HE-B-52-WEG 설치 지침 매뉴얼 - 페이지 2

{카테고리_이름} Hi-Velocity HE-B-52-WEG에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Hi-Velocity HE-B-52-WEG 6 페이지. He-b-52 electrical box c/w weg variable speed drive

HE to HE-B-52 Air Handler Control Box Upgrade Installation
IMPORTANT -
Before you begin, ensure input voltage of WEG Controller matches line input voltage to air handler.
Fig. 1 - 52 Series Air Handler
3. Unbolt the two blower housing bolts from the
air handlers center plate, using a 7/16" wrench.
(Fig. 3)
4. Remove motor/blower module from air handler
by sliding it out. (Figs. 4a, 4b)
5. Unplug motor plug from control board. Remove
motor ground wire (green/yellow) from the bolt
connecting it to the controls plate. (Figs. 5a, 5b)
2
www.hi-velocity.com
1. Turn off power to the air handler, and allow 5 minutes for power stored in
capacitors to dissipate. Remove large access door from air handler. (Fig. 1)
2. Unplug all thermostat and power wired connections from air handler, in
order to remove motor/blower module. (Figs. 2a, 2b)
Large
Access Door
-2-
Module HEB-52 WEG
Circuit Box Installation (2/6)
Fig. 2a
Fig. 3
Fig. 4a
Fig. 5a
Fig. 2b
Fig. 4b
Fig. 5b
© 1995-2022 Energy Saving Products Ltd.
© 1995-2022 Energy Saving Products Ltd.