92
PHONE LINE MONITOR ENABLE
UL: see Inst. Instructions for requirements
93
No. OF REPORTS IN ARMED PERIOD
PER ZONE (Swinger Suppression)
DOWNLOAD INFORMATION (
94
DOWNLOAD PHONE No.
[USA: 18667984828]
[Canada: 18774673940]
95
RING COUNT FOR DOWNLOADING
96,
97
INITIALIZE/RESET DEFAULTS
98,
99
EXIT COMMANDS
PAGER OPTIONS (
160-
160 PAGER 1 PHONE No.
161 PAGER 1 CHARACTERS
162 PAGER 1 REPORT OPTIONS
163 PAGER 2 PHONE No.
164 PAGER 2 CHARACTERS
165 PAGER 2 REPORT OPTIONS
172 PAGER DELAY OPTION FOR ALARMS
MISCELLANEOUS SYSTEM FIELDS (*174-*181)
174 CLEAN ME REPORT OPTIONS
(for ESL smoke detectors)
177 DEVICE DURATION 1, 2
(used in *80 Menu mode-Device Actions 5/6)
181 50/60 HERTZ AC OPERATION
1
NOTE: Output Device must
either be programmed to be
STOPPED in field
STOPPED by Code + # + 8 +
output number.
94,
95)
|
|
|
|
|
Enter up to 20 digits, 0–9; #+11 for '
spaces. If fewer than 20 digits, exit field by pressing
UL: downloading may be performed only if a technician is at the site.
[15]
NOTE: Do not enter "0" if using
4285/4286 Phone Module.
These are commands, not data fields. See page 2.
These are commands, not data fields. See page 2.
172)
|
|
|
|
|
Enter up to 20 digits. 0–9; #+11 = '
|
Enter the optional prefix characters, up to 16 digits.
0–9; #+11 = '
[0]
|
|
|
|
|
Enter up to 20 digits. 0–9; #+11 = '
|
Enter the optional prefix characters, up to 16 digits.
0–9; #+11 = '
[0]
[3]
[0]
1
[0]
Entry 1:: 0 = disabled, 1-15 = 1 min - 15 min
[0,0]
2
Entry 2:
0 = Keypad display when line is faulted
1 = Keypad display plus keypad trouble sound
80 or
2 = Same as "1", plus programmed output device
STARTS. If system is armed, external sounder
activates also.
0 = Unlimited Reports UL: must be "0"
[0]
1 = 1 report pair
2 = 2 report pairs
|
|
|
|
|
|
|
|
'; #+12 for '#'; #+13 for a 2-second pause. Do not fill unused
0 = Disable Station Initiated Download;
1–14 = number of rings (1–9, # +10 =10, # +11 =11,
# +12 =12, # +13 =13, # +14 =14);
15 = answering machine defeat (# +15 =15).
|
|
|
|
|
|
|
|
'; #+12 = '#'; #+13 = 2-second pause.
|
|
|
|
|
|
|
|
'; #+12 = '#'; #+13 = 2-second pause.
Select from the following options:
0 = no reports sent
1 = Opens/closes all users
4 = All alarms and troubles
5 = All alarms / troubles, and opens/closes for all users
12 = Alarms / troubles for zones entered in zone list 9
13 = Alarms / troubles for zones entered in zone list 9,
and opens/closes for all users
|
|
|
|
|
|
|
|
'; #+12 = '#'; #+13 = 2-second pause.
|
|
|
|
|
|
|
|
'; #+12 = '#'; #+13 = 2-second pause.
See field *162 for reporting options. (use zone list 10 if
using options 12 or 13).
0 = none, 1 = 1 minute, 2 = 2 minutes, 3 = 3 minutes
This delay is for ALL pagers in the system.
0 = disable; 1 = Clean Me signal reports;
Note: If Clean Me is enabled, you must enter "3" in
field
56 programming for zone 1 response time.
0 = 15 seconds
[0] [0]
1 = 30 seconds
2
2 = 45 seconds
3 = 60 seconds
4 = 90 seconds
5 = 2 minutes
0 = 60 Hz; 1 = 50 Hz
– 6 –
(#+10 = 10 min; #+11 = 11 min; #+12 = 12 min;
#+13 = 13 min; #+14 = 14 min; #+15 = 15 min)
SIA Installations: Must be set
for option 1 or 2.
|
|
|
|
|
|
. To clear entries from field, press
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6 = 2-1/2 min
#+11 = 7 min
7 = 3 min
#+12 = 8 min
8 = 4 min
#+13 = 10 min
9 = 5 min
#+14 = 12 min
#+10 = 6 min
#+15 = 15 min
94
.