ADEMCO LYNXR-EN 빠른 시작 매뉴얼

{카테고리_이름} ADEMCO LYNXR-EN에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ADEMCO LYNXR-EN 8 페이지.

®
4XL.N6WDUW*XLGHIRU/<1;5/<1;5DQG/<1;5(1
8 /
LYNXR and LYNXR-EN are not intended for UL985 Household Fire applications unless a 24-hour backup
battery (P/N LYNXRCHKIT-HC) is installed.
Introduction
This Quick Start Guide can help you install the rechargeable LYNXR/LYNXR24 and LYNXR-EN quickly and easily
by providing the basic steps for installation using the built-in defaults. For more detailed information and important
notes, refer to the LYNXR Series Installation Instructions.
The following steps assume that one of the system's default tables will be used.
For programming data values and Powerline Carrier Devices other than those listed in the default tables, see the
Installation Instructions.
Default Table Summary
Zone
1
-------
2
front door
3
back door
4
window
5
motion detector
6
-------
7
-------
8
-------
9
-------
26
loop 3 arm away
27
loop 2 disarm
28
loop 4 arm stay
29
loop 1 restore device 1
30
loop 3 arm away
31
loop 2 disarm
32
loop 4 arm stay
33
loop 1 restore device 1
92
99
Master User Code
Installer Code
Duress Code
Entering Program Mode: installer code + 8 0 0
Interactive Mode
* 56 Enhanced Zone Programming
* 83 Sequential Mode
*84 Assign Zone Voice Descriptors
Exiting Program Mode: * 99 allows re-entry into the Program mode using Installer Code + 8 0 0.
* 98 inhibits re-entry into the Programming mode using the Installer Code.
NOTES: • Tables 2 and 4 support the automatic paging feature (open/close events reported to pager phone number),and a Powerline
Carrier Device programmed as device 8, which closes and stays closed upon burglary alarms and restores after bell timeout. For
other applications or actions (e.g., using a pulsing siren), see the *80 Device Programming Menu Mode section of the Installation
Instructions.
• Primary report format for all tables is Ademco's Contact ID reporting. Tables 2 and 4 also use Contact ID for secondary
reporting. Tables 1, and 3 use 4+1 format for secondary reporting.
• Table 2 records all events in the event log. Tables 1, 3, and 4 record only alarms, alarm restores, troubles, and trouble restores
in their event logs.
Table 1
-------
front door
back door
Garage door
motion detector
smoke detector
-------
-------
-------
loop 3 arm away
loop 2 disarm
loop 4 arm stay
loop 1 restore device 1
loop 3 arm away
loop 2 disarm
loop 4 arm stay
loop 1 restore device 1
duress
silent alarm
audible alarm
1-2-3-4
4-1-1-2
------
/<1;56HULHV
Table 2
-------
front door
back door
window
window
window
window
motion detector
smoke detector
loop 3 arm away
loop 2 disarm
loop 4 close device
loop 1 restore device 1
loop 3 arm away
loop 2 disarm
loop 4 close device
loop 1 restore device 1
duress
silent alarm
1-2-3-4
6-3-2-1
2-5-8-0
Used to Program
Zone characteristics, report codes, and serial numbers
5800 Series transmitter serial numbers
Voice descriptors for each zone
K5966 5/01 Rev. B
Table 3
-------
front door
back door
window
window
window
window
motion detector
smoke detector
loop 3 arm away
loop 2 disarm
loop 4 close device
loop 1 restore device 1
loop 3 arm away
loop 2 disarm
loop 4 close device
loop 1 restore device 1
duress
silent alarm
1-2-3-4
4-1-1-2
------
Table 4
duress
1-2-3-4
4-1-1-2
------