Overview
The 529 Compressor provides a comprehensive suite of controls:
THRESHold: The level at which compression begins (+10dB to -20dB)
Threshold LED: Indicates when the input audio crosses the selected THRESHold level
RATIO: The amount of compression applied after threshold (1.5:1 to
ATTACK: The time it takes for the compressor to respond (1 to 50 m/sec)
RELEASE: The time it takes the compressor to return to unity gain (.05 to 4 seconds)
METER: Selects OUTPUT or INPUT as the source for the stereo VU meter
VU (Stereo VU Meter): Stereo 10-segment LED VU meter (selectable OUTPUT or INPUT)
GR (Gain Reduction) Meter: 10-segment LED gain reduction meter
MAKE UP: Selects AUTOmatic or MANUAL MAKE UP gain
GAIN: Manual MAKE Up gain control (0dB to +24dB of output gain when MANUAL is engaged)
TYPE: NEW (feed-forward) or OLD (feedback) detection path topology
KNEE: The characteristic of the response curve at the onset of compression.
®
THRUST
: Patented circuit that inserts a filter before the RMS detector
OUT: Toggles to swich gain reduction in or out or engages hard bypass
Compressor Controls
THRESHold
5 2 9 S t e r e o C o m p r e s s o r
THRESHold: Sets the level at which compression begins
Continuously variable range between +10dB and -20dB
Detented rotary pot for easy recall
Threshold LED: Illuminates when the input audio crosses the level set
by the THRESH control
Illuminates in red when active
3
:1)
∞
A P I