Automated Processes, Inc. 529 운영자 매뉴얼 - 페이지 7

{카테고리_이름} Automated Processes, Inc. 529에 대한 운영자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Automated Processes, Inc. 529 14 페이지. Stereo compressor

Compressor TYPE

The 529 Compressor can be set to operate in two circuit topologies that determine where the signal
that feeds the RMS detector comes from:
OLD: Feed-Back topology: The RMS detector receives the signal from after the VCA
NEW: Feed-Forward topology: The RMS detector receives the signal from before the VCA

NEW (Feed-Forward)

In a feed-forward compressor, the RMS detector normally gets its signal from a split of the input sig-
nal. (The detector path can alternately get its signal from a Side Chain Input.) With this method, the
RMS detector sends a signal to the VCA that is an exact ratio of the desired compression set by the
RATIO control. This is how many new VCA based compressors work. This can yield more aggressive
compression and a harder, more affected sound.

OLD (Feed-back)

In a feed-back compressor, the RMS detector gets its signal from the output of the gain reduction de-
vice (VCA). This is how older API 525, 1176 type, and 660 type compressors work. This yields a
smoother, softer, more transparent sound.
5 2 9 S t e r e o C o m p r e s s o r
5
A P I