CAUTION
! 
●Be sure to unplug the pump unit.
●Replace the diaphragms and the valves with new ones at least once a year to one and
a half year regularly in order to maintain their initial performance.
●For chamber block replacement, be sure to change both chamber blocks at the same time.
●The  rod  employs  powerful  permanent  magnets.  Therefore,  be  sure  to  remove  your
watch and any other precision machines before operation as they may be affected by
the strong magnetic force.
●Do not put the actuating rod close to a magnetic card, magnetic disk or other magnetic
media as the data may be destroyed.
STEP
STEP
REMOVAL OF THE CHAMBER BLOCKS
1
1
To remove the upper housing. 
(Refer to
Remove the sound absorber. 
Pull out the L-tube from the casing block.
STEP
STEP
2
2
Remove the 4 screws holding the chamber block 
and the casing block. 
(4 screws on each side)
STEP
STEP
3
3
Remove  1  U-lock  nuts  from  one  side  holding  the 
diaphragm mounting block to the rod. 
●Use the nut driver to loosen (or tighten) the U-lock nut.
2
REMOVING UPPER HOUSING