Gooseneck / Pedestal Mounting

Lightning prone areas must
!
use Surge protector
24v dc PSU
Power (2x1mm / 16 gauge)
Tip: For shorter distances, some installs may mount transmitter on pedestal for convenience.
Range test first! For high security applications, it is recommended to locate the transmitter INSIDE
the property perimeter.
24v dc PSU
TIP: Most technical calls received are due to installers using CAT5 or alarm cable to power
the unit. Neither are rated to carry enough power (1.2 amp peak). Please use following
cable...
Up to 2 metres (6 feet) – Use minimum 0.5mm
Up to 4 metres (12 feet) – Use minimum 0.75mm
Up to 8 metres (24 feet) – Use minimum 1.0mm
P a g e
| 4
transmitter
Intercom
Transmitter
603 Range
Power cable (2x1mm / 16 gauge)
Screened CAT5 included. (8m / yards MAX)
!
Power (2x1mm / 16 gauge)
2
(20 gauge)
2
2
(16 gauge)
Keep High!
Intercom
Transmitter
603 Range
(18 gauge)
Speech
point
Keep High!