AirCycler g2-k 교육 매뉴얼 - 페이지 16

{카테고리_이름} AirCycler g2-k에 대한 교육 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. AirCycler g2-k 20 페이지.
AirCycler g2-k에 대해서도 마찬가지입니다: 설치 및 사용 설명서 (11 페이지), 설치 테스트 매뉴얼 (2 페이지), 설치 테스트 매뉴얼 (2 페이지)

AirCycler g2-k 교육 매뉴얼
6.3 DISABLING THE AIRCYCLER® G2
Warning: It is not recommended to turn off the AirCycler® if the unit is used as a ventilation controller.
3.4.1 Remove the top of the controller from the base to stop power to the unit and remove any button battery in the
unit. Place the unit back on the base.
3.4.2 On power up, all icons will be illuminated for 3 seconds. Within 3 seconds of powering up press the DOWN arrow
to enter set up mode for Calculated Time.
3.4.3 The first setting is the number of minutes of outside air (OA SET) to be brought into the house per hour. Set this
number zero. Press MODE
3.4.4 (Only available if FanConnect is installed) The next setting is the number of minutes of exhaust fan run time. Set
this number to zero . Press MODE
3.4.5 The next setting is the operating 'ON' time. Because you are disabling the system, leave this at the factory
defaulted 'NO'. If your system is currently set to 'YS', press the down arrow to change to 'NO'. Press MODE
3.4.6 (Only available if FanConnect is installed) The next setting is the number of minutes the bathroom exhaust fan
attached to your FanConnect switch will operate after the switch is moved to the auto (down) position. This allows the
fan to continue to run after you have turned the switch off to continue to clean out the air in the bathroom (moisture,
cleaning, beauty products, etc). Set this number to zero to completely disable this feature or leave as is. Press MODE
THE UNIT IS DISABLED
16
AC DOC 8.5
REV 7/2020