7.0 INSTALLATION TESTING GUIDE
Testing the AirCycler® g2-k completed installation is an easy two step process:
STEP 1
Test the FanConnect
STEP 2
Test thermostat, damper and furnace connection and operation
STEP 1
a. With the thermostat off, turn on the FanConnect™
switch.
b. Confirm the exhaust fan is running
c. The AirCycler® g2 display should show the exhaust (bath)
fan is ON and the outside fresh air damper is open (OA)
d. Confirm the outside fresh air damper is open (OA icon)
e. Turn off exhaust fan
STEP 2
a. Make sure exhaust fan is off (delay time may be running and
EXH icon will show)
b. Turn thermostat FAN switch to ON
c. Confirm AirCycler® g2 display shows FAN and damper
open (OA).
d. Confirm furnace fan is running
e. Remove AirCycler® g2 from it's base. Furnace fan should
shut off
f. DONE! Replace AirCycler® g2 controller on it's base