HID EDGE EVO ESH400 설치 매뉴얼 - 페이지 2

{카테고리_이름} HID EDGE EVO ESH400에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. HID EDGE EVO ESH400 12 페이지. Hi-o networked controller

HID EDGE EVO ESH400 설치 매뉴얼
EDGE EVO Hi-O Networked Controller
EH400
1

Power Analysis

Before starting installation, determine which components will be used in the system and analyze the power requirements to avoid
over-loading the EDGE EVO Hi-O Networked Controller (EH400).
The following steps illustrate sizing power requirements for the system.
Step 1 - Identify System Components
Identify the components that will be used in the system. A typical installation may include the following components:
Step 2 - Create System Layout
Using the components identified in "Step 1 - Identify System Components" on page 2, create the system layout.
In this example, the EH400 is connected to the remote server through an Ethernet connection and manages door
peripherals over the Hi-O bus. The EDM-M receives inputs from the Door Position Switch and REX Switch to drive the
Magnetic Lock and Local Exit Alarm outputs.
Unprotected
Area
Hi-O iCLASS
Reader
Figure 1 - System Layout Example
2
INSTALLATION GUIDE
Door Position Switch – Detects when the door is open or closed.
Magnetic Lock – Holds the door locked.
Request to Exit (REX) Switch – Unlocks the door when exiting the secured area.
Local Exit Alarm – Sounds an alarm upon an unauthorized exit.
EDGE EVO Hi-O Edge Door Module (EDM-M) – Connects peripheral devices to the Hi-O bus.
EDGE EVO Hi-O Networked Controller (EH400) – Provides access control and manages all peripherals
around the door.
Hi-O iCLASS Wiegand Reader – Provides entry into the secured area.
ted
Protected Area
Hi-O Networked
Hi-O N
Con
Controller
SS
Ethernet Data
CANbus Data
Door Position
Switch
Magnetic Lock
Magne
Local Sounder
Exit Alarm
Remote Area
Ethernet Switch
Door
Module
Physical Access
Control Server
(real-time functions
not required )
REX Switch
©2009 - 2012 HID Global Corporation. All rights reserved.
82000-920, D.1