Gainlab Audio GLA-TC2 캘리브레이션 매뉴얼 - 페이지 9
{카테고리_이름} Gainlab Audio GLA-TC2에 대한 캘리브레이션 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Gainlab Audio GLA-TC2 18 페이지.
Gainlab Audio GLA-TC2에 대해서도 마찬가지입니다: 매뉴얼 (13 페이지)
Now go back to 3.1 and check if in Bypass mode you still measure 0V in between TP1 and TP2.
Most likely it will stay as you set up earlier. Repeat 3.1 and 3.2 if needed.
3.3 Bypass measurement (Right channel)
Switch Mode to Bypass.
Measurement process: Measure voltage between TP4 and TP5
points
Adjust: VR4
Target: to see 0V on volt meter
Error margin: 0.1V
3.4 Hicomp measurement (Right channel)
Switch Mode to HiComp.
Measurement process: Measure voltage between TP4 and TP5
Adjust: VR10
Target: to see 0V on volt meter
Error margin: 0.1V