DynaLock
705 Emmett Street
Ph/ 860.582.4761
The Series 3001xTJ31 is a 700 pound holding force top jamb-mounted electromagnetic lock designed to secure a
double-inswinging pair of doors. The lock requires both installation procedures as described herein and in the
separate wiring instructions included.
Typical installations of the lock on double-inswing doors:
Care must be taken that the lock face and armature face are kept free of dirt, rust, paint, or any other obstruction
which may interfere with the lock and armature making good contact. These faces may be cleaned with a non-
abrasive pad and wiped with an oil dampened cloth.
Familiarize yourself with the door and frame conditions. The lock must mount rigidly to the face of the door frame
header. The door mounted armature is supplied with an adjustable mounting bracket and hardware that allows it to
pivot slightly to compensate for reasonable misalignment.
After mechanical installation is complete the lock needs to be wired to a 12 or 24 VDC/VAC power source. Once low
voltage power is supplied the unit is fully operational. All other wiring is for selected options. Refer to the separate
wiring instructions included for further information.
3001xTJ31 MANUAL - FORM 3001TJ-001
Bristol, CT 06010
?
Fx/ 860.585.0338
?
INSTALLATION DESCRIPTION
HANDLING
MECHANICAL INSTALLATION
ELECTRICAL INSTALLATION
SERIES 3001xTJ31
ELECTROMAGNETIC LOCK
INSTALLATION INSTRUCTIONS
Page 1
11/02