Fill the coolant liquid tank to maximum level indicated. Use the specific
cooling liquids, never use anti-freeze, tap water or any other electricity
conductor liquid.
For the system to work correctly, we must empty the air from the circuit.
Connect the flexible purge hose in the cooling water outlet.
(blue connector).
Place an empty container at the free end of the flexible hose, then, after
discharging the air, the coolant liquid will come out.
Switch on the equipment until the coolant liquid is made to come out
through the flexible hose by pressure and immediately afterwards switch it
off.
Remove the flexible purge hose and connect the desired setup (torch / set of cables).
In installations with sets of cables, it is advisable to carry out an
intermediate purge of air at the outlet from the wire feed unit.
If the cooling system has been stopped for a long time, the pump shaft could have blocked due to the action of the liquid.
Remove the side cover from the cooling unit.
With the aid of a screwdriver, manually turn the pump shaft.
Repeat the air discharge process from the installation.