The red indicator light will signal that the valve is now in the closed position, and that you
need to check all areas where you have placed a sensor to determine what plumbing
product caused the system to activate .
The valve will remain closed until the unit is manually reset on the WaterCop
the plumbing problem is fixed, reset the WaterCop
the face of the WaterCop
at right .
Note: If major repairs are needed to correct the plumbing system, it is recommended that
the manual shut-off valve upstream of the WaterCop
Close the main water shut-off valve and unplug the WaterCop
the plumbing system .
Note: In case of a power failure, the WaterCop
will need to use the manual shut-off valve to turn the water off in case of an emergency . When power is restored, the
WaterCop
will remain in its last known position indicated by the red or green lights on the face of the unit .
®
WaterCop
®
Actuator
Max . working pressure
Ambient temperature
Enclosure
Voltage
Current
Accessories
Sensor Signal Repeater
Sensors
FCC Information
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
•
Reorient or relocate the receiver;
•
Increase the separation between the equipment and receiver;
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected;
•
Consult the dealer for help .
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operation of the device .
Caution:
The user is cautioned that changes and modification made to the equipment without the approval
of the manufacturer could void the user's authority to operate this equipment.
DynaQuip Controls • 10 Harris Industrial Park • St. Clair, MO 63077
Tel. 800-545-3636 • Fax. 636-629-5528 • www.watercop.com
6
. Valve will open and green indicator will be lit . See illustration
®
®
Specifications
125 PSIG
35° to 105° F
Polycarbonate
12 VDC includes 120 VAC adaptor
0 . 8 5 AMPS (Full Load)
120 VAC 47mA
3 VDC (2AA Batteries) 10mA
®
by pressing "OPEN" (green circle) on
®
also be closed during the repairs .
®
before making repairs on
®
cannot operate . If the power is out, you
Valve
Valve
Valve Seals
Flow Data
Valve Size Cv = Gpm flow @ 1 PSI pressure drop
1/2" NPT
3/4" NPT
1" NPT
1-1/4" NPT
For cold water applications
panel . After
Full-Port, Lead-Free Brass, NPT
RTFE (Reinforced Teflon)
19
34
52
77