FT-66xx Quick Start Guide
Step 9: Tunnel – Generate CA Key
This step will only be performed once. You should not repeat it for each FT device.
A USB flash drive was included with your FT-66xx. Insert the USB flash drive into one of the USB
ports on the FT-66xx. Go to Tunnel – Generate CA Key form. Fill out the form. All of the fields,
except the password fields, are informational. It really doesn't matter what you put in them, but its best
to use information meaningful to you.
The two password fields are the most critical. On this form, you are creating the password. Enter the
same password in both places. Make sure to use a password you can remember. You will need it later
when you generate local keys.
Press the "submit" button, then wait patiently. Key generation can be a slow process. Also, make sure
to read any error messages. USB flash drives sometimes fail to register correctly. Upon error, it may
be necessary to remove the USB drive, wait 5 or so seconds, then reinsert the drive.
If you forget your password, there is no way to recover it. Your only option is to generate new a CA
key, which will overwrite the old one.
Step 10: Tunnel – Generate Local Key
This step will be performed for each FT device. As a reminder, make sure the FT's clock has been set
before proceeding.
Insert the USB flash drive, containing your CA Key, into one of the USB ports on the FT-66xx.
Navigate to the Tunnel – Generate Local Key form. For the name field, use a unique and descriptive
name for the device. For example, the server FT-66xx could be named "Home Office Server" and the
client FT-66xx could be named "Remote Office Client". The lifetime field specifies the number of
days that the key is to be certified. Unless you plan to frequently change your keys, its best to choose a
big number.
For the password field, enter the same password you set when you generated the CA key.
Press the "submit" button, then wait patiently. Key generation is a slow process. Also, make sure to
watch for any error messages. USB flash drives sometimes fail to register correctly. Upon error, it
may be necessary to remove the USB drive, wait 5 or so seconds, then reinsert the drive.
Remove the USB Flash drive and store it in a safe place. You will need it in the future if you plan to
add more client FT-66xx devices to your server.
Step 11: Tunnel – Mode
Navigate to the Tunnel – Mode form and select whether the FT-66xx is operating as the server or the
client.