PTT24 Manual
5. Connect the PTT24 to 48 VDC Power
Each PTT24 has 2 diode protected power connectors. The power connectors are 3 position
Phoenix type connectors. Each connector has Frame Ground, positive and negative power
connections.
6. Connect the Alarm IN and Alarm Out
The Alarm In can come from another PTT24 or from the channel bank. The Alarm Out can
be connected to another PTT24, to a SCADA system for remote reporting, to some local
external alarm signal device, etc. The Alarm In and Alarm out are contact closures. Alarm
Off is open, Alarm On is a closed relay connection. The PTT24 will operate with or without
the Alarm In or Alarm Out connected.
7. Select the Control Channel
Select the Control Channel to be monitored by the PTT24. For 12 channel operation the
channel must be from 1 to 12. For 24 channel operation the channel must be from 1 to 24.
The Power LED will flash if an invalid channel is selected. .