Dynaset HPW 180/90-115 사용 설명서 - 페이지 14

{카테고리_이름} Dynaset HPW 180/90-115에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Dynaset HPW 180/90-115 19 페이지. Hydraulic high pressure water pumps

Dynaset HPW 180/90-115 사용 설명서
14
2
WATER FLOW RATE
TOO SMALL
3.
WATER PRESSURE
TOO LOW
4.
INTENCE PULSATING
OF WATER
PRESSURE
2.1
Insufficient hydraulic flow or
pressure.
2.2
Nozzle of your pressure tool
undersized.
2.3
Pressure loss in delivery hose.
3.1
Insufficient hydraulic pressure
or flow.
3.2
Nozzle of pressure tool
oversized.
3.3
Wear-out of nozzle.
3.4
Insufficient water supply.
3.5
Water pressure unloader valve
set too low.
4.1
Some of water intake and
pressure valves are open or
damaged.
4.2
Water intake line breathes
causing pump cavitation.
4.3
Water intake line's diameter
to small, resulting in pump
cavitation.
4.4
Excessive hydraulic flow,
when HPW-pump runs too
fast.
HPW - HIGH PRESSURE WATER PUMPS
TROUBLESHOOTING
2.1
Adjust the hydraulic flow to the demanded
level at required pressure.
2.2
Verify the nozzle sizing and replace with
proper one.
2.3
Verify the hose sizing and replace with proper
one.
3.1
Adjust the hydraulic pressure to the
demanded level at required hydraulic oil flow.
Pressure loss should be minimized - do not use
hoses of too small diameter or/and of an
excessive length.
3.2
Verify the nozzle sizing and replace with a
proper one.
3.3
Replace the nozzle.
3.4
Check and fix the problem. Use pressurised
water supply if available.
3.5
Check and re-adjust to specification.
4.1
Check water valves, clean thoroughly or
repair.
4.2
Check water intake line and fix the problem.
4.3
Verify the hose sizing and replace with proper
one.
4.4
Adjust the hydraulic flow to the demanded
level.
May 2014