Dynaset HPW 180/90-115 사용 설명서 - 페이지 15

{카테고리_이름} Dynaset HPW 180/90-115에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Dynaset HPW 180/90-115 19 페이지. Hydraulic high pressure water pumps

Dynaset HPW 180/90-115 사용 설명서
15
5.
CLOSING THE WATER
PRESSURE LINE DOES
NOT DROP PRESSURE
TO FREE
CIRCULATION MODE.
Hydraulic system
starts to run through
the pressure relief
valve, emitting
excessive heat.
Models with water
pressure unloader
valve.
6.
LEAKAGES
5.1
Insufficient hydraulic
pressure in relation to
pumping fluid pressure,
adjusted with water pressure
unloader valve.
5.2
Defective water pressure
unloader valve.
6.1
Hydraulic oil leakages.
6.2
Pumping fluid leakages.
6.3
Hydraulic-pumping fluid
commixture dropping from
leakage detecting bores.
HPW - HIGH PRESSURE WATER PUMPS
TROUBLESHOOTING
5.1
Adjust the hydraulic pressure up as much as
necessary to enable proper operation of
water pressure unloader valve.
Note that the maximum hydraulic pressure
should not be overrun !
If boosting the hydraulic pressure is not
possible, the water unloader pressure setting
should be dropped.
5.2
Repair or replace water pressure unloader
valve.
6.1
Check the tightness of component mating,
tighten screws.
Replace when necessary sealings of pump's
mated surfaces.
Check and tighten/replace couplings.
6.2
Check the tightness of component mating,
tighten screws.
Replace when necessary sealings of pump's
mated surfaces.
Check and tighten/replace couplings.
6.3
If the draining from leakage detectors exceeds
rate of 10 drops per minute, pump's sealings
should be replaced.
The rule applies to dropping of hydraulic fluid,
pumping fluid and their commixture.
May 2014