Autool C100 사용자 설명서 - 페이지 3
{카테고리_이름} Autool C100에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Autool C100 5 페이지. Fuel system cleaner
Without return hose connecting:
The hose line connection of theengine without returnhose is
shown as in Fig.02.
Disconnect the fuel supply hoses (E, F) of engine fuel system
(wrap the connector when disconnecting the connector), and
then choose a proper connector and connect it to the E end.
Reconnect the fuel outlet hose of the unit well and make the
fuel return hose hanging. See Fig.02.
Stop the other end of the disconnected end (F) with a proper
stopper, (use when the fuel pump has the fuel return function
only) or remove the fuse of fuel pump or disconnect the power
cable of fuel pump.
Fig.02
1-C100 Cleaner & Tester; 2-Engine; 3-stopper; 4- Fuel-inlet hose
to engine; 5-Auto tank; 6-Auto filter; 7- Engine fuel supply hose;
8-Auto fuel pump;
3
The pictures
Pour the mixture of gasoline and detergent into steel bottle of
the C100.
Close the valve of C100's fuel-outlet pipe and open the valve
of C100's air-inlet port and then connect to the compress air.
Adjust the pressure of air within 0.3 to 0.4MPa( 3 to
4kgf/cm2) by air control valve.
Connect the fuel supply adaptor of C100 to fuel supply pipe of
the car fuel system, and open the ball valve. Check if it has
some leaking between all the connections. There must have
no any leaking when doing the cleaning work.
Start engine to start flushing the fuel system.
Drain out the pressure in the C100's bottle after flushing, and
then disconnect the C100.
Restore all of the pipes of the fuel system and check there
have no leaking.
Note: The connection ways for carburetor fuel system is
same to electronic fuel injection system. The pressure in
carburetor fuel system must be 0.07~0.35 kgf/cm2.
4