Clearance
Adequate clearance as shown below for servicing and air circulation — room
temperature should be maintained between 40°F and 100°F when the motors
are running.
A fl at, level fl oor that provides stable support.
Protection from the weather and direct sunlight.
A power source within 3 ft. of back-center that provides a dedicated,
breaker-protected circuit.
PLUMBING REQUIREMENTS
1. 1/2 in I.D. minimum pipe size.
2. Pipe connection is to be located within 3 ft of
center back of compressor.
3. Install per all Local and State plumbing codes.
WARNING!
Fire Hazard! Running motors generate heat. Do not store fl ammable
liquids or objects such as clothing, mops, or brooms near or above the unit.
ELECTRICAL REQUIREMENTS
1. 3 wire single phase 115 vac or 230 vac. All
voltage ratings ± 5%.
2. Green Wire is to be grounded to a suitable
system ground.
3. Power supply must be on a dedicated circuit.
4. See data tag for appropriate breaker size.
5. Power supply connection is to be located
within 3 ft of center back of compressor.
6. Install per all local and State electrical codes.
1 .8 00.6 24.2 793
C Series Installation Guide

Site Requirements

Compressor Site Requirements
Site Requirements
3