After the Goal Post sensors have been identified it is necessary to disperse any debris and particulates that
have built up on the sensors over time. Take your canned air and focus it in the area of each Goal Post
sensor and disperse any debris that appears on both Goal Post sensors.
4)
After the debris has been dispersed take your contact cleaner and spray (heavily) both Goal Post sensors.
Once you have sprayed down the Goal Post sensors utilize your Q-tips to swab any dried up ink on the PCB
board and the black Goal Post sensor.
Hint: Compress the Q-tip between your fingers to allow for the Q-tip to pass between the Goal Post sensor.
5)
At this time the goal post sensors have been cleaned. Connect the service station back to the ribbon cable and
insert the service tray back into the service channel.
For additional support call the Vivid Data Support Team at 1-855-848-4332 Option 2!
Figure 3. Unlocking & Locking Ribbon Cable