WARNING: When pneumatic tools are used do not exceed the woking pres-
sure of 150 PSI (10 atm) – Danger of air hose explosion
When the job is done disconnect the tool from the vacuum machine
WARNING: Changes in the electrical connection of the vacuum cleaner
could cause serious damages, even the death of the operator, and irrepara-
ble damages to the vacuum cleaner.
(B1) WHITE SLIDE SWITCH (I II) (optional)
POSITION "I": low speed
1 user – 1 flexible hose
POSITION "II": high speed
2 users – 2 flexible hoses
(U) ORANGE INDICATOR LIGHT
Connected to a pressure switch, when it lights means that the cartridge filter
(essential filter) is clogged and it must be replaced.
(U1) RED INDICATOR LIGHT
It turns on when the thermal protection that stops the motor is activated. The
thermal protection works when the temperature of the air coming out from
the motor is about 85°C. The motor overheating is due to an obstructed filter
cartridge.