Emerson FB2100 현장 교체 매뉴얼 - 페이지 9
{카테고리_이름} Emerson FB2100에 대한 현장 교체 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Emerson FB2100 16 페이지. Flow computer i/o terminal board
Emerson FB2100에 대해서도 마찬가지입니다: 현장 교체 매뉴얼 (16 페이지), 현장 교체 매뉴얼 (8 페이지), 현장 교체 매뉴얼 (14 페이지), 현장 교체 매뉴얼 (16 페이지)
FB2100/FB2200 Flow Computer I/O Termination Board Field Replacement Guide
8.
Line up the new replacement I/O termination board with the screw holes and reattach it
using the eight screws. Torque screws to 4 to 6 in-lbs. (0.5 to 0.7 N m).
9.
If present, place the optional 8-channel expansion I/O board on the posts, and carefully line it
up to avoid bending pins. Gently press the expansion I/O board down onto the I/O
termination board. Reattach the 8-channel expansion I/O board to the I/O termination board
using the four screws you removed in step 5. Torque screws to 1 to 2 in-lbs (0.1 to 0.2 N m).
10.
Take the CPU enclosure (with the HMI module attached) and line up the CPU enclosure's
captive fastening screws with their matching holes on the I/O assembly. Press the enclosure
screws onto the holes and hold it there while tightening each of the captive fastening
screws. Torque screws to 7 to 9 in-lbs. (0.8 to 1.0 N m).
11.
Connect the intermediate cable to the sensor module and make sure it has clearance.
D301805X012
November 2020
7