Fuses

There are several fuses in this unit that protect it from shorts, spikes, and other such
electrical problems that may possibly damage the unit.
The HRT is protected internally by a 2 amp self-resetting fuse. This is not user
serviceable, but will automatically reset once the short is removed.
The entire unit is protected by a 20 amp
automotive type fuse, located on the
back of the unit. If your unit completely
stops working, this fuse should be
checked.
Seven additional fuses are
located inside the control
box. These fuses protect
the seven high-current
light outputs. If only one
of your outputs is not
working correctly, it may
be that the corresponding
fuse for that output has
blown.
Cover Removal - Remove the four Philip head screws located on the back of the
unit. DO NOT REMOVE THE SCREWS ON THE FRONT OF THE UNIT!
Slide the top cover off the front face of the unit. Take care not to
damage the microphone cord during this procedure. This cover
can be removed completely from the siren unit. Carefully slide
the cover over the microphone and set it aside.
After the cover has been removed, find the location of the fuses (see the diagram
below). Each high current light output is protected with a separate 20A
automotive blade fuse. Check each of these fuses to make sure they are all
working properly, and none have blown.