Connection to SXHM Controller

Connect an ADi dosing pump directly to Agrowtek's SXHM hydroponics sensor to form a powerful, autono-
mous pH and EC set-point dosing system. Operate a single, dual or quad AgrowDose pump and configure
each pump as an EC part or pH up or down part. Automatically maintains pH and EC concentrations with a
simple repeating recipie dosing method.
A direct-link connection between a SXHM sensor and ADi pump requires Agrowtek's cross-over adapter.
IMPORTANT! ONLY use cross-over adapters provided by Agrowtek. Do not use other cross-over adapters or cross-over
cables unless they are constructed exactly as diagramed on the cross-over diagram. Incorrect cross-over adapters or cables
can cause damage to the equipment.
Please see the "MDX" product manual for more information on setting up and installing the MDX mini-dos-
ing system.
MDX System Instruction Manual

Cross-Over Cable

A custom cross-over cable can be constructed as an alternative to using the cross-over adapter and two
standard, straight Ethernet cables as shown in the diagram above. The cross-over wiring MUST match the
diagram below.
Pins 7 & 8 carry 24Vdc power and must be straight through or damage may result to the equipment.