The main user guide should only be used for reference purposes,
please use this guide for initial programming.
Your softener should already have been set up with the basic settings in
The only settings you should need to enter are the Time of Day, Day of
Week and the Water Hardness where applicable.
Button descriptions.
Before starting this process please ensure that the softener is connected
correctly to the water, waste and power supply.
Quick Set Up Guide
the factory.
Initial Power Up.
Plug the transformer into the rear of the control panel; this
is located to the left top corner of the panel if viewing from
the front. Once the power is connected the display may
briefly show the valve type (255 or 268). The valve type
will be printed on the side of the valve and should also
appear on the delivery documentation. On occasions the
display may flash between the time and regeneration
symbols, press the set button to clear this.
Note. During the set up process the display may revert to
normal mode (after 25 seconds).
By repeatedly pressing the up or down arrow button you
can scroll to the part of the set up programme you require.
If you receive an ERR3 message allow the cam shaft to
turn for a few moments and this code should disappear. If
the cam does not move check that the Cam Shaft is fitted
correctly and that the optical sensor is in position.
1. Down arrow. Used to scroll
down or increment through
a group of choices.
2. Set. Used to accept a setting to
store in the memory.
3. Up arrow. Used to scroll up or
increment up through a group
of choices.
4. Regenerate. Used to command
the controller to regenerate.