Trouble shooting.
Following is a guide to some of the most common problems that may
arise; please consult this section before contacting your supplying dealer as
most problems are easily cured using this information.
Troubleshooting
Proble m
ERR 1 is displayed
ERR 2 is displayed
ERR 3 is displayed
Four dashes displayed
Possible Cause
Controller power has been
connected and the control is not
sure of the state of operation.
Controller power does not match
50 or 60 Hz.
Controller does not know the
position of the cam shaft. Camshaft controller to return to home position.
should be rotating to find home
position.
Camshaft is not turning during
ERR 3 display.
If the camshaft is turning for more
than five minutes to find home
position.
Power failure occurred.
Solution
Press the up arrow and the control
should reset.
Disconnect and reconnect the power
If the problem persists obtain the
appropriate controller or AC adapter
for either 50 or 60 Hz power.
Wait for two minutes for the
The hour glass should be flashing
on the display indicating the motor
is running.
Check that the motor is connected.
Verify that the motor wire harness is
connected to the motor and
controller module. Verify the optical
sensor is connected and in place.
Verify that the motor gear is engaged
with the cam gear.
If everything is connected try
replacing in this order.
Wire harness.
Motor.
Optical sensor.
Controller.
Verify that the optical sensor is in
place and connected to the harness.
Verify that the camshaft is
connected correctly.
Verify no debris is clogging any of
the cam slots.
If motor continues to rotate
indefinately replace the following in
this order.
Wire harness.
Motor.
Optical sensor.
Controller.
Press SET to reset time display.