Coral Mistral Series 설치 및 운영 매뉴얼 - 페이지 14
{카테고리_이름} Coral Mistral Series에 대한 설치 및 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Coral Mistral Series 15 페이지. Cabinet
Troubleshooting
Proble m
9. Valve will not draw brine.
10. Uses more or less salt than A) Foreign matter in valve causing
the setting.
11. No water flow display on
metered valves.
12. Run out of conditioned water A) Impropper regeneration.
between regenerations.
Possible Cause
A) Low water pressure.
B) Drain line restricted.
C) Injector plugged.
D) Injector defective.
E) Air check closes prematurely.
incorrect flow rates.
A) Bypass valve in bypass.
B) Meter probe not connected to
C) Restricted turbine rotation due to Remove turbine and clean. Turbine
debris in turbine.
B) Incorrect regeneration setting.
C) Incorrect hardness or capacity
settings.
D) Water hardness has increased.
E) Restricted turbine rotation.
F) No or not enough salt in cabinet. Salt level should be above water level.
Solution
Fit pump (contact dealer).
Check drain line is not blocked or
kinked.
Clean injector and screen.
Replace injector.
Put control into brine draw C2 to
check. Repair or replace if needed.
Remove brine control and clean our
any debris. Put system through a
regeneration to flush valve.
Open bypass.
Connect correctly.
should rotate freely, if not replace it.
Repeat regeneration after checking
the correct regenerant dosage is set.
Set correct salt setting.
Set to correct values.
Set hardness to correct value.
See 11 c.