Product Installation Guidelines
REMOVE & INSPECT CARTRIDGE
Handle
1. Remove Handle
−
Ensure the water supply is closed.
−
Unscrew the handle and remove the grub
screw.
−
Remove the handle body
3. Remove and Inspect Cartridge
−
Remove Cartridge
−
Inspect for debris and clean. Replace if
necessary.
Note: For cartridge replacement, use WaterMarked
Standard/Universal 35mm Flat Cartridge. For more
information, please contact Galvin Engineering
© Galvin Engineering Pty Ltd
Grub screw
Handle body
Cartridge
Retaining nut
2. Remove Cap and Retaining Nut
−
Unscrew the cap and retaining nut from
the body
4. Reassemble
−
Reverse steps 1 to 3 to reassemble
ensuring the orientation is correct.
−
Test for leaks and correct operation.
Version 2.1, 2 December 2021, Page 5 of 6
Cap