Product Installation Guidelines
REMOVE & INSPECT CARTRIDGE
Handle
1. Remove Handle
Ensure the water supply is closed.
Unscrew the handle and remove the grub
screw.
Remove the handle body
3. Remove and Inspect Cartridge
Remove Cartridge
Inspect for debris and clean. Replace if
necessary.
Note: For cartridge replacement, use WaterMarked
Standard/Universal 35mm Flat Cartridge. For more
information, please contact Galvin Engineering
© Galvin Engineering Pty Ltd
Grub screw
Handle body
Cartridge
Retaining nut
2. Remove Cap and Retaining Nut
Unscrew the cap and retaining nut from
the body
4. Reassemble
Reverse steps 1 to 3 to reassemble
ensuring the orientation is correct.
Test for leaks and correct operation.