Galvin Engineering GalvinAssist 41985CP 설치 매뉴얼 - 페이지 4
{카테고리_이름} Galvin Engineering GalvinAssist 41985CP에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Galvin Engineering GalvinAssist 41985CP 5 페이지. Cp hand shower with inverted lh t 700x1100 ss hygienic grab rail
Product Installation Guidelines
5. Fit grab rail into wall mount plate and
tighten lock nut firmly.
7. Cradle Installation
-
Fit the shower cradle to the grab rail as
shown.
-
Position the cradle as desired then tighten
the cover of the cradle.
Elbow
9. Connect Flange Wall Outlet Elbow
-
Fit elbow over spigot and secure with grub
screw.
-
Using 2.5mm hex key supplied, tighten 5mm
grub screw.
© Galvin Engineering Pty Ltd
-
-
-
Hex Key
-
the connection is secured, then turn on water
supply. Check for any leaks.
Version 1, 1 June 2022, Page 4 of 5
6. Screw flange cover to wall mount plate.
Flow Regulator
Spigot
8. Connect Flange Wall Outlet Elbow
Apply thread tape to wall spud. When
applying thread tape or sealant to the wall
spud, ensure the opening is not obscured.
Failure to do so may restrict or block the flow
restrictor, affecting the flow of water.
Remove spigot by loosening grub screw in
elbow.
Fit spigot to wall spud, ensuring the flow
regulator is in place and not damaged when
tightening the spigot.
10. Check Shower for correct operation
and leaks
Connect hose and shower head ensuring
th
Version 1, 25
May 2022, Page 4 of 5
Grub Screw