3. Remove flange screws
Unscrew the flange screws
5. Remove cartridge nut and check cartridge
Unscrew cartridge nut and remove cartridge.
Check the cartridge for wear and damage.
Replace if required with cartridge
replacement available through your supplier
Check and clean the body of all debris
WARRANTY
The warranty set forth herein is given expressly and is the only warranty given by the Galvin Engineering Pty
Ltd. With respect to the product, Galvin Engineering Pty Ltd makes no other warranties, express or implied.
Galvin Engineering Pty. Ltd. hereby specifically disclaims all other warranties, express or implied, including but
not limited to the implied warranties of merchantability and fitness for a particular purpose.
Galvin Engineering Pty Ltd products are covered under our manufacturer's warranty available for download from
www.galvinengineering.com.au Galvin Engineering Pty Ltd expressly warrants that the product is free from
operational defects in workmanship and materials for the warranty period as shown on the schedule in the
manufacturer's warranty. During the warranty period, Galvin Engineering will replace or repair any defective
products manufactured by Galvin Engineering without charge, so long as the terms of the Manufacturer's
warranty are complied with.
The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for
breach of warranty, and Galvin Engineering Pty Ltd shall not be responsible for any incidental, special or
consequential damages, including without limitation, lost profits or the cost of repairing or replacing other
property which is damaged if this product does not work properly, other costs resulting from labour charges,
delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions,
chemical, electrical or any other circumstances over which Galvin Engineering has no control. This warranty
shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or
alteration of the product.
4. Remove faceplate (with button) and flange
6. Re-assemble
Re-assemble, by reversing steps 5 to 1.
Ensuring sealing compound is used when
connecting water supply and outlet.
Turn on water and check for correct operation