SERVICE AND MAINTENANCE
1. Turn off water
Turn off the water supply.
Open shower outlet to release pressure.
4. Remove face plate and flange
WARRANTY
The warranty set forth herein is given expressly and is the only warranty given by the Galvin Engineering Pty Ltd. With respect to the product,
Galvin Engineering Pty Ltd makes no other warranties, express or implied. Galvin Engineering Pty. Ltd. hereby specifically disclaims all other
warranties, express or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose.
Galvin
Engineering
Pty
Ltd
www.galvinengineering.com.au
workmanship and materials for the warranty period as shown on the schedule in the manufacturer's warranty. During the warranty period,
Galvin Engineering will replace or repair any defective products manufactured by Galvin Engineering without charge, so long as the terms of
the Manufacturer's warranty are complied with.
The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty, and Galvin
Engineering Pty Ltd shall not be responsible for any incidental, special or consequential damages, including without limitation, lost profits or
the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from labour
charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical, electrical or any
other circumstances over which Galvin Engineering has no control. This warranty shall be invalidated by any abuse, misuse, misapplication,
improper installation or improper maintenance or alteration of the product.
2. Remove control knob
Unscrew tamper proof screw from control
knob.
Pull out control assembly from the body.
5. Remove catridge nut and check catridge
Unscrew cartridge nut and remove
cartridge.
Check the cartridge for wear and
damage. Replace if required with
cartridge replacement available through
your supplier.
Check and clean the body of all debris.
products
are
covered
under
Galvin Engineering Pty Ltd expressly warrants that the product is free from operational defects in
3. Remove grub screw
Unscrew grub screw to remove facplate
and flange. (Note: Grub screw must be
retrieved or replaced for re-assembly).
6. Re-assemble
Re-assemble, by reversing steps
5 to 1.
Turn on water and check for correct
operation.